Meyer Sound ULTRA-X40 Wide Coverage Loudspeaker
SPECIFICATIONS
ACOUSTICAL1
COVERAGE TRANSDUCERS
AUDIO INPUT
Operating Frequency Range2 Frequency Response3 Phase Response Linear Peak SPL4
Low Frequency High Frequency
Type Maximum Common Mode Range
Input Impedance
Nominal Input Sensitivity
Type Total Output Power6 THD, IM, TIM
Cooling
Connector Automatic Voltage Selection Safety Rated Voltage Range Turn-on and Turn-off Points
53 Hz – 19.5 kHz
57 Hz – 18 kHz ± 4 dB
89 Hz – 18 kHz ±45°
132.5 dB (M-noise), 130 dB (Pink Noise), 131 dB (B-noise)
Rotatable horn: 110° x 50°
Two 8 in cone drivers; 4 Ω nominal impedance
One 3 in diaphragm compression driver connected to a rotatable horn; 8 Ω nominal impedance
Differential, electronically balanced
±15 V DC, clamped to earth for voltage transient protection
10 kΩ differential between pins 2 and 3
0 dBV (1.0 V rms) continuous is typically the onset of limiting for noise and music
3-channel, Class-D 1950 W peak <0.02%
Convection
powerCON 20 input with loop output
90–265 V AC, 50–60 Hz
100–240 V AC, 50–60 Hz
90 V AC turn-on, no turn-off; internal fuse protection above 265 V AC
0.27 A rms (115 V AC); 0.25 A rms (230 V AC); 0.29 A rms (100 V AC) 1.9 A rms (115 V AC); 1.0 A rms (230 V AC); 2.2 A rms (100 V AC)
3.1 A rms (115 V AC); 1.5 A rms (230 V AC); 3.4 A rms (100 V AC)
6.9 A rms (115 V AC); 3.4 A rms (230 V AC); 7.9 A rms (100 V AC) <20 A peak
Connectors |
XLR 3-pin female input with male loop output; optional XLR 5-pin connector to accommodate both balanced audio and RMS signals. |
Wiring5 |
Pin 1: Chassis/earth through 1 kΩ, 1000 pF, 15 V clamp network to provide virtual ground lift at audio frequencies Pin 2: Signal + |
Input Level |
Audio source must be capable of producing of +20 dBV (10 V rms) into 600 Ω to produce the maximum peak SPL over the operating bandwidth of the loudspeaker. |
AMPLIFIER |
AC POWER
CURRENT DRAW
Idle Current Maximum Long-Term Continuous Current (>10 sec) Burst Current (<1 sec)7 Maximum Instantaneous Peak Current Inrush Current
RMS NETWORK (OPTIONAL) |
|
Two-conductor twisted-pair network that reports all operating parameters of amplifiers to system operator’s host computer. |